SOMATOM go.Sim
Simulation reinvented

SOMATOM go.Sim
SOMATOM go.Sim
 
Contact Us

SOMATOM go.Sim is pending 510(k) clearance, and is not yet commercially available in the United States.

SOMATOM go.Sim1 is a highly flexible, intuitive CT simulator. With fully integrated hardware and software tailored specifically to your requirements, it increases certainty and reduces the likelihood of errors. It also features advanced algorithms, AI-powered OAR autocontouring, and excellent soft-tissue contrast potentially decreasing target margins. What’s more, it is designed to care for both patients and users – with a calming environment, a simple operating concept, and a single vendor service contract. 

SOMATOM go.Sim1 can increase workforce productivity and optimize clinical operations. It helps you get the full picture faster so you can spend less time managing CT simulation and more time focusing on patients.

Features & Benefits

Clinical Use

Reinventing CT simulation with SOMATOM go.Sim1 – a highly flexible, intuitive CT simulator that we designed in collaboration with over 300 RT specialists – radiation oncologists, medical physicists, dosimetrists, RTTs, and financial decision makers – to give us insights into your world. The result is a groundbreaking approach to CT simulation. It will give you everything you need to achieve the ultimate starting point for optimal RT planning, and will help you produce the most successful outcomes possible.


Be certain in simulation

60% of all RT incidents are caused by human errors

as a consequence of manual operations and data exchanges5

  • Successful CT simulation needs efficient and fail-safe workflows
  • Current processes mean users have to switch between multiple software and hardware solutions

 

Lack of integration leads to errors and uncertainty in CT simulation.

Integration is a key factor to avoid potential error prone CT simulation workflow

SOMATOM go.Sim1 comes with fully integrated hardware and software tailored specifically to your requirements. It offers unparalleled operational flexibility, and intuitive guidance.

This is a workflow that gives you certainty in simulation: It's smooth, fast and is able to deliver the reproducible and user-independent results you need.

Your benefits

  • Seamless and less error-prone processes thanks to the new mobile workflow
  • Streamlined laser QA thanks to fully integrated Direct Laser
  • Intuitive and guided CT simulation thanks to GO technologies

Drive precision for contouring

Poor scope for accurate contouring hinders confident treatment planning

  • Modern treatment techniques require precise planning
  • CT simulation must consistently deliver high-quality patient modeling for the tumor and surrounding organs
  • Yet the data provided for contouring are often not precise enough

Contouring is the main cause of variability in radiotherapy planning.7


Drive precision for OAR contouring

Radiation oncology professionals have to spend time manually correcting poor autocontouring

  • The quality of autocontouring depends on the quality of the CT images
  • Suboptimal image quality (caused by metal artifacts, poor soft-tissue contrast, etc.) leads to suboptimal autocontouring7,8

In the worst-case scenario, radiation oncology professionals have to redo the OAR contouring entirely by hand.

Consistent OAR contours generated directly in the simulator with DirectORGANS4

SOMATOM go.Sim1 features an AI-powered OAR autocontouring that
automates and standardizes key steps in the CT simulation pathway. The
high-quality information arrives directly as TPS-ready data.

An autocontouring algorithm needs a specific type of image to perform contouring

DirectORGANS4 optimizes the images specifically for the algorithm.
This paves the way for consistent OAR contouring powered by AI.

DirectORGANS4 is a revolutionary, AI-based organs-at-risk contouring solution. The result reduces unwarranted variations with high-quality contours that approach the level of consensus-based contours.

Your benefits

  • OAR contouring directly in the system, no need for manual interaction
  • Optimized images designed for the deep-learning algorithm
  • High-quality contours that approach the level of consensus-based contour

Drive precision in target contouring

A powerful combination of three innovative solutions delivers confident tumor visualization, precise target contours, and a straightforward 4D workflow: iMAR4 reduces metal artifacts, DirectDensity3,4 unlocks optimal kV settings with a single calibration curve, and respiratory motion management2 optimizes scan parameters based on the patient’s breathing.

Your benefits

  • Confident tumor visualization thanks to automated metal artifact reduction with iMAR4
  • Precise target contours with optimum kV imaging and a single calibration curve thank to DirectDensity3,4
  • Straightforward 4D workflow thanks to comprehensive respiratory motion management4
DirectDensity3,4 unlocks a wider range of tube voltages in CT scanners for better imaging quality while maintaining similar dosimetric accuracy.10 Tianyu Zhao, PhD
Assistant Professor in Radiation Oncology, Washington University School of Medicine, Department of Radiation Oncology, St. Louis, MO, USA

Care for patients and users

Anxious patients and time-pressured operators can lead to suboptimal CT simulation

  • Current CT simulation can create anxiety for patients and pressure for operators
  • Operators have to spend a lot of time outside the examination room
  • Installing and maintaining a multi-vendor system is complex and time-consuming

49% of patients feel distressed and anxious.11

If operators are under less time pressure, they can devote more time to caring for patients and generating high-quality results. If patients feel at ease, their CT simulation will be more successful.

Improve the patient experience with a patient centric design, co-created with RT professionals

  • Total freedom over how and where you set up the simulation, and more time with your patient thanks to the mobile workflow
  • A calming environment for the patient thanks to the ring mood lighting
  • More comfort for patients thanks to the large 85-cm bore

Benefit from a shorter learning curve and easier vendor management with an all-in-one solution

  • One revolutionary user interface
  • One call center
  • One maintenance appointment
  • One service contract
  • One training session

SOMATOM go.Sim1 creates a comfortable and calming environment for patients, and enables staff to spend more time at their side.

Technical Specifications

Bore size85 cm
sFoV60 cm
Acquired slices/reconstruction slices32/64
Z-axis coverage1.92 cm
Rotation time0.354, 0.5, 1.0 s
Table load227/3074 kg (TG-66 compliant)
System footprint4 m2/43 ft2 (surface area covered by gantry and moving table top)
Min. room requirement17.3 m2/186.2 ft2

 

Related Products, Services & Resources

1SOMATOM go.Sim is pending 510(k) clearance, and is not yet commercially available in the United States.

2syngo.via and syngo.via CT Dual Energy DirectSPR is required.

3As shown by measurements with a Gammex 467 Tissue Characterization Phantom comparing [T]standard reconstruction and DirectDensity reconstruction. Image value to relative electron/mass density conversion for the standard reconstruction was based on a two-linear-equations approach with individual calibration for each tube voltage. For DirectDensity images, a single tube-voltage-independent linear conversion was used.
DirectDensity reconstruction is designed for use in Radiation Therapy Planning (RTP) only. DirectDensity reconstruction is not intended to be used for diagnostic imaging.

4Optional.

5Greenwalt J et al. Reducing errors in radiation therapy through electronic safety checklists. Applied Radiation Oncology. 2014: 5–9.

6Up to 4 additional tablets are optional.

7Jameson MG et al. A review of methods of analysis in contouring studies for radiation oncology. J Med Imaging Radiation Oncol. 2010; 54(5): 401–10.

8Wu X, Udupa JK, Odhner D, et al. Knowledge-Based Auto Contouring for Radiation Therapy: Challenges in Standardizing Object Definitions, Ground Truth Delineations, Object Quality, and Image Quality. Int J Radiat Oncol Biol Phys. 2017; 99(2): E740.

9Cheung CW, Leung KY, Lam WW, et al. Application of Model-based Iterative Reconstruction in Auto-contouring of Head and Neck Cases. Scientific Informal (Poster) Presentation at: LL-ROS-TH Radiation Oncology and Radiobiology Lunch Hour CME Posters; 2012 Nov 29; Chicago, IL.

10The statements by Siemens Healthineers’ customers described herein are based on results that were achieved in the customer’s unique setting. Since there is no “typical” hospital and many variables exist (e.g., hospital size, case mix, level of IT adoption) there can be no guarantee that other customers will achieve the same results.

11Kelly E et al, Reduced patient anxiety as a result of radiation therapistā€led psychosocial support: a systematic review, J Med Radiat Sci Sep; 64(3): 220–231 2017.