MAMMOMAT Revelation
With 50⁰ Wide-Angle Tomosynthesis. Superior by design.

MAMMOMAT Revelation
 
Product brochure

 

Experience superior cancer detection with our flagship tomosynthesis system

In breast care, screening programs are on the rise. While 2D mammography is still the standard technology, tomosynthesis is beginning to grow into the screening space. Radiologists and breast care professionals need to work more efficiently than ever before, while their patients demand a more comfortable examination with reliable and quick results.

MAMMOMAT Revelation – our flagship tomosynthesis system – helps address these challenges and bring tomosynthesis one step closer to screening. Clinically proven, the unique 50° Wide-Angle Tomosynthesis in MAMMOMAT Revelation helps you gain valuable insights, enabling more accurate1,2 and earlier detection of breast cancer. Providing the highest depth resolution3 and mass detectability4, MAMMOMAT Revelation is designed for superior cancer detection, personalized care, and high cost-effectiveness.

  • Designed for superior cancer detection1,2: Realize the full potential of tomo with 50°.
  • Designed for personalized care: Embrace the uniqueness of every woman.
  • Designed for cost-effectiveness: Experience efficiency in every step.

What's new with MAMMOMAT Revelation?

Insight 2D – the Synthetic Twin of FFDM

Our synthetic mammogram, Insight 2D, offers breast images FFDM-like image impression5. This allows you to perform fast comparison6 and easy breast density evaluation7 without the added dose of an additional 2D examination. Insight 2D eases the transition from FFDM to tomosynthesis as it takes the 2D viewing and reading habits of radiologists into account.

Features & Benefits

Highly valuable tomosynthesis is only possible with a 50⁰ Wide-Angle

With our 50° Wide-Angle Tomosynthesis, we provide a superior, highly accurate method for detecting cancers and facilitating a reliable diagnosis.This will result in a significant change for breast care professionals, for radiologists, and – most importantly – for the many women and their families personally affected by breast cancer. We stand for tomosynthesis that is accurate, patient-centric, and economic.

Why is 50° so accurate?

At Siemens Healthineers, we put accuracy first. With the highest number of 25 projections our 50° Wide-Angle Tomosynthesis helps gain deeper insights, enabling more accurate1,2 and earlier detection. Only with 50° Wide-Angle Tomosynthesis can you achieve the highest mass detectability4 and a depth resolution that is 3.5 times higher than with a narrow angle3.

Experience the 50° Wide-Angle

Move the slider to the left or right to see the objects from several different angles. Experience how a wider angle can provide you with more, valuable information in order to assess overlapping breast tissue and increase diagnostic certainty.

 

Embrace the uniqueness of every woman

Patient anxiety and the growing need for personalized pathways are challenges in breast care. Every woman is different, and MAMMOMAT Revelation embraces their individual uniqueness. Personalized Soft Compression helps to reduce discomfort during the exam. While Insight Breast Density enables instant risk stratification and sound decision-making for the next steps – before the patient leaves. With relaxed and calm patients, it’s much easier to achieve high image quality and avoid rescans; this is supported by the calming MoodLight. While PRIME enables up to 30% less dose8, addressing a major concern of many women.

 

Experience efficiency in every step

Whether providing screening or diagnostic services, efficiency and productivity are key to keep costs down and patient experience high.

Key technologies

 

TiCEM

Get additional diagnostic information fast with our Titanium Contrast Enhanced Mammography (TiCEM), a cost-effective alternative to MRI as an adjunct examination.

Insight BD

Visual classification of breast density can be challenging. With Insight BD, you can receive objective, volumetric classification supporting you in doing an instant risk stratification right at the acquisition workstation.

50° Wide-Angle Biopsy

Profit from our unique 50° Wide-Angle technology that results in a target accuracy of +/- 1mm. Reduce biopsy procedure time thanks to easy one-click targeting and the integrated specimen scanner InSpect.

Clinical Use

Clinical Videos

Increase your diagnostic accuracy - with 50° Wide-Angle Biopsy

Watch the clinical workflow of a tomosynthesis-guided breast biopsy procedure with MAMMOMAT Revelation.

Experience efficiency in every step with 50° Wide-Angle Biopsy

Watch the 50° Wide-Angle Biopsy workflow with MAMMOMAT Revelation and learn how our system helps you to work more efficiently.

Expand your diagnostic insights - with TiCEM

Learn how Titanium Contrast Enhanced Mammography (TiCEM) can expand your diagnostic insight.

Experience smooth workflows with Personalized Soft Compression and our one-click philosophy

Watch the 2D Screening workflow with MAMMOMAT Revelation and learn how you can enhance patient comfort throughout the workflow.

The impact of angular range in tomosynthesis - The Cookie Experiment

See the benefits of increased object separation as a result of the highest depth resolution on the market.3

Mass detectability with wide-versus narrow-angle tomosynthesis

Watch the case of a 55-year old woman who noticed a lump in her breast and learn how a wider angle increases mass detectability.

Clinical images

mammomat revelation
Narrow-angle tomosynthesis (left), 50° Wide-Angle Tomosynthesis - better tissue separation as a result of the highest depth resolution on the market4 (right)
mammomat revelation
FFDM: Suspicious mass, BI-RADS 4 (left), Insight CEM: Categorization as BI-RADS 5 after contrast enhancement of the lesion, biopsy confirmed IDC (right)
mammomat revelation
FFDM (left), Insight 2D -  The synthetic twin of FFDM (right)
mammomat revelation
Insight 2D with Flavor 0 (1), Insight 2D with Flavor 2 (2), Insight 2D with Flavor 5 (3), Insight 2D with Flavor 1 (4)

Technical Specifications

System specification

Detector technologyAmorphous Selenium (aSe)
Detector size24 cm x 30 cm (9.5“ x 12“)
X-ray tube anode materialTungsten
FilterAnode-filter combinations: W/Rh, W/Ti
Swivel range+180° to -180°, motorized, isocentric rotation with preselectable rotation angle

 

Related Products, Services & Resources

1Compared to FFDM; Zackrisson S, Lång K, Rosso A, Johnson K, Dustler M, Förnvik D et al. (2018) One-view breast tomosynthesis versus two-view mammography in the Malmö Breast Tomosynthesis Screening Trial (MBTST): A prospective, population-based, diagnostic accuracy study. The Lancet Oncology. doi:10.1016/S1470-2045(18)30521-7.

2Compared to FFDM; PMA P140011/S001 & P140011/S003; Georgian et al. (2019): Can Digital Breast Tomosynthesis Replace Full-Field Digital Mammography? A Multireader, Multicase Study of Wide-Angle Tomosynthesis. AJR 2019, pp. 1-7. doi.org/10.2214/AJR.18.20294

3Maldera et al. (2016): Digital breast tomosynthesis: Dose and image quality assessment. Physica Medica, pp. 1-12.

4Scaduto et al. (2018) Impact of angular range of digital breast tomosynthesis on mass detection in dense breasts," Proc. SPIE 10718, 14th International Workshop on Breast Imaging (IWBI 2018), 107181V (6 July 2018); doi: 10.1117/12.2318243

5Data on file

6Data on file

7Talk of Prof. Van Ongeval at Breast Care Day 2019, Vienna: https://www.siemens-healthineers.com/mammography/informationgallery/videos

8Compared to grid-based acquisition with MAMMOMAT Revelation, depending on breast thickness - L.B. Larsen, A. Fieselmann, H. Pfaff, T. Mertelmeier Performance of grid-less digital mammography acquisition technique for breast screening: analysis of 22,117 examinations Presentation B-1025 ECR 2015.

9Data on file

Please note that the following features are options: 50° Wide-Angle Tomosynthesis with Insight 2D and 3D, 50° Wide-Angle Biopsy with InSpect, Insight BD, TiCEM, Personalized Soft Compression, and MoodLight