Simultaneous Multi-Slice
Setting the pace in MRI accelleration for TSE and DWI

Simultaneous Multi-Slice
With Simultaneous Multi-Slice TSE and Simultaneous Multi-Slice DWI we can enable significant time savings from head to toe

Simultaneous Multi-Slice
Simultaneous Multi-Slice acceleration provides sharper visualization of a labral tear in MR arthrography with T1w TSE

Simultaneous Multi-Slice
TSE compared to Simultaneous Multi-Slice TSE for knee scans

Simultaneous Multi-Slice
TSE compared to Simultaneous Multi-Slice TSE for ankle scans

Simultaneous Multi-Slice
Significantly accelerate MSK scans with Simultaneous Multi-Slice TSE Save up to 46% exam time in Foot/ Ankle examinations

Simultaneous Multi-Slice
Significantly accelerate entire MSK scans with Simultaneous Multi-Slice TSE Save up to 46% exam time in knee examinations

Simultaneous Multi-Slice
Diffusion compared to Simultaneous Multi-Slice Diffusion
University Hospital NYU, School of Medicine, New York, USA

Simultaneous Multi-Slice
Diffusion compared to Simultaneous Multi-Slice Diffusion
University Hospital NYU, School of Medicine, New York, USA

Simultaneous Multi-Slice
fMRI BOLD compared to fMRI BOLD, Simultaneous Multi-Slice
University Hospital NYU, School of Medicine, New York, USA

Simultaneous Multi-Slice
Diffusion compared to Simultaneous Multi-Slice Diffusion

Simultaneous Multi-Slice
Simultaneous Multi-Slice (SMS) is a paradigm shift in MRI – helping cut MSK scan times by up to 46%, reducing DWI scan times throughout the body, and significantly improving temporal resolution for BOLD fMRI.
SMS TSE1 enables scan time reductions as a factor of slice acceleration. Thereby, entire Foot/Ankle scans, for example, can be performed in only 7 instead of 13 minutes while maintaining image quality. Time savings may also be invested in higher spatial resolution or thinner slices.
SMS DWI maximizes productivity for diffusion-weighted imaging of the brain, breast, abdomen and pelvis. With acceleration factors of up to 8, SMS for DTI and BOLD bring advanced techniques, such as pre-surgical mapping, into clinical routine.
General Requirements
System
Minimum Software Version
syngo MR E11C (for MAGNETOM Aera, Skyra, Prisma, Avantofit, Skyrafit, Prismafit with SMS DWI and SMS BOLD)
syngo MR XA11A1 (for MAGNETOM Sola and Vida with SMS TSE, SMS DWI, SMS BOLD)
Other
Also available for systems upgraded to:
MAGNETOM Prismafit
MAGNETOM Skyrafit
MAGNETOM Avantofit
Please note: Additional technical prerequisites may apply. Upon receiving your request, your local Siemens representative will clarify whether your system meets the requirements.
Related Products, Services & Resources
1The products/features (here mentioned) are not commercially available in some countries. Due to regulatory reasons their future availability cannot be guaranteed. Please contact your local Siemens organization for further details.