Biograph mCTA wide bore and more

Expand your potential with Biograph™ mCT to serve more patients and grow your business through a high standard of imaging and clinical flexibility.
Features & Benefits

Set the standard in PET/CT
The value of PET/CT is in the details -- more precise information leads to greater potential for an earlier diagnosis and a more definitive treatment strategy, helping to improve patient outcomes. Our entire product portfolio is built on technology that all together adds up to more. Our wide range of features expand your clinical capabilities and deliver excellent lesion detectability, spatial resolution, and quantification accuracy -- letting you bring a high standard of care to more patients.

Leverage an open design
Streamline user experience and address a broader patient population with design purposefully built on our key technologies. A large 78 cm bore, short 135 cm tunnel and 227 kg (500 lb) table capacity support the examination of a heavier patient population, allow for easier patient positioning, offer space for additional therapy accessories and help increase patient comfort.

Move your business forward
Biograph mCT is configured to address challenging patient situations, giving you the opportunity to maximize your return on investment. A remarkably scalable PET/CT platform, it's designed to evolve with your business, helping you to attract referrals now and well into the future.

Uniquely suited to your needs
Biograph mCT may include features such as FlowMotion continuous bed motion and TrueV1, which increases the axial field of view to enable two times faster scans or half the injected dose without compromising image quality. Other available features like time of flight1 show up to 200% improvement in signal to-noise ratio2 for better image quality, lower dose or faster scan speed.

AIDAN Platform
Our intelligent imaging platform for Biograph™ PET/CT scanners that supports the demanding processing power of AI-based solutions.
Click plus (+) to find out our features

Exclusive bed design and wide bore
LSO crystals
CT capability
iMAR
SAFIRE
Whole-body dynamic imaging
Time of flight
TrueV extended PET field of view
QualityGuard
HD•PET
FlowMotion AI
FAST PET Workflow AI
Multiparametric PET Suite AI
OncoFreeze™ / OncoFreeze AI
- Exclusive bed design and wide bore
Zero differential deflection for accurate attenuation correction and TG-66 compliant along with a 78-cm bore to support bariatric imaging and easier positioning of radiation oncology devices - LSO crystals
4 x 4 x 20 mm for fast scintillation with great detection efficiency for any PET isotope, even short-lived cardiac isotopes - CT capability
Definition class CT offers 40-, 64-, or 128-Edge-slice CT configurations
- Exclusive bed design and wide bore
- iMAR
Iterative algorithm for metal artifact reduction - SAFIRE
CT
iterative reconstruction to reduce dose and maintain image quality - Whole-body dynamic imaging
Routine whole-body dynamic imaging enable by FlowMotion™ continuous bed motion - Time of flight
Up to 2x improvements in signal to noise and image contrast - TrueV extended PET field of view
Additional PET detector ring enabling faster scans or lower injected dose - HD•PET
Create visually sharper images incorporating point spread function (PSF) - QualityGuard
Uses intrinsic radioactive properties of Lutetium present on LSO detectors to automatically calibrate itself - FlowMotion
AI Personalize scans based on anatomy and standardize imaging protocols based on indication - FAST PET Workflow AI
Creation of Auto Ranges and Auto Data Export - Multiparametric PET Suite AI
Adds the metabolic rate and distribution volume to the standard SUV image without the need for an invasive measurement - OncoFreeze™ / OncoFreeze AI
Motion management without extending scan time and, if preferred, without the need for a gating device
- iMAR
Technical Specifications
Gantry |
|
Bore diameter: | 78 cm |
Tunnel length: | 136 cm |
Table capacity: | 227 kg (500 lb) |
* Optional
CT |
|
Generator power: | 80 kW, 100 kW* |
Rotation times: | 1.0, 0.5, 0.33, 0.30*, 0.28* s |
Tube voltages: | 70, 80, 100, 120, 140 kV |
Iterative reconstruction: | SAFIRE* |
Metal artifact reduction: | iMAR* |
Slices: | 40, 64, 128 |
* Optional
PET |
|
Axial field of view: | 16.4, 22.1* cm |
Crystal size: | 4 x 4 x 20 mm |
Time of flight performance: | 540 ps |
* Optional
1
Optional
2
Based on internal measurements. Data on file.