Dimension Xpand Plus Integrated Chemistry System

The Dimension Xpand Plus Integrated Chemistry System
Dimension Xpand Plus Integrated Chemistry System
 
Bizle İletişime Geçin

The Dimension® Xpand® Plus Integrated Chemistry System combines chemistry, STAT and specialty testing on a single, compact, easy-to-use system.

Özellikler ve Faydalar

Full Range Integrated Capability for maximum efficiency in a compact space

"The Siemens ISD assays on the Dimension® Systems provide a number of advantages, including decreased turnaround time—instead of batching samples, which can take two or three hours to perform, we can run samples
(in random access) in about 30 minutes."

Raffick Bowen, MT(CSMLS), PhD, DCIChem, FCACB, DABCC
Stanford University Medical Center

Compact yet powerful

  • Comprehensive menu – over 90% of critical assays
  • 47 assays onboard concurrently

True Integration

  • Simultaneous immunoassay and chemistry processing when used with Heterogeneous Immunoassay module
  • One sample area
  • Common reagent area

User-friendly

  • No manual reagent or sample preparation
  • Load and go reagents without instrument pause
  • Low calibration frequency
  • Minimal maintenance

Built-in Automation

  • Auto rerun at lab-defined “panic” values
  • Lab-defined auto-dilution without operator involvement
  • Automatic reflex testing
  • Autocalibration for electrolytes
  • Sample level sense warns of low volumes prior to processing
  • Patented cuvette system automatically produces cuvettes for use and seals them for disposal

 

Ölçümler

Anemia
Ferritin

Cardiac
CKMB Mass
CKMB Activity
CardioPhase® hsCRP
Myoglobin
NT-proBNP
Troponin I

Diabetes
Fructosamine*
Hemoglobin A1c

Drugs of Abuse/Toxicology
6-Acetylmorphine (6-AM)§
Acetaminophen
Amphetamines
Barbiturates, Urine
Barbiturates, Serum§
Benzodiazepines, Urine
Benzodiazepines, Serum§
Buprenorphine§**
Cannabinoids (THC)
Cocaine Metabolite
Ecstasy
Ethyl Alcohol
Fentanyl††
Methadone
Methaqualone§
Opiates
Oxycodone§
Phencyclidine
Propoxyphene§
Salicylate
Tricyclic Antidepressants§


General Chemistry

Acid Phosphatase
Alanine Aminotransferase (ALT)
Albumin (BCP)
Aldolase*
Alkaline Phosphatase
Ammonia
Amylase
Aspartate Aminotransferase
Bilirubin, Direct
Bilirubin, Total
Calcium
Carbon Dioxide, Enzymatic
Chloride
Cholesterol
Cholinesterase
Creatinine
Creatinine, Enzymatic
Creatine Kinase
Dibucaine Number*
Gamma Glutamyltransferase (GGT)
Glucose
HDL Cholesterol
Hemolyzed Glucose§
Iron
Lactate
Lactate Dehydrogenase (L-P)
LDL Cholesterol
Lipase
Magnesium
Microalbumin
Pancreatic Amylase*
Phosphorus
Potassium
Sodium
Total Iron Binding Capacity
Total Protein
Total Protein (CSF/Urine)
Triglycerides
Urea Nitrogen (BUN)
Uric Acid 

Immunosuppressant Drugs
Cyclosporine
Cyclosporine, Extended Range
Everolimus**
Mycophenolic Acid
Sirolimus
Tacrolimus

Oncology
Free PSA
Total PSA

Reproductive Endocrinology
hCG

Specific Proteins
α1-Acid Glycoprotein*
β-2 Microglobulin Latex*
Apolipoprotein A-1*
Apolipoprotein B*
Anistrestolysin O (ASO)*
Ceruloplasmin*
Complement C3
Complement C4
CRP
CRP Extended Range
Haptoglobin*
Immunoglobulin A
Immunoglobulin G
Immunoglobulin M
Kappa light chains*
Lambda light chains*
Lipoprotein (a) Ultra*
Prealbumin
Rheumatoid Factor (RF)*
Transferrin

Therapeutic Drug Monitoring
Amikacin§
Caffeine§
Carbamazepine
Digitoxin
Digoxin
Gentamicin
Lamotrigine**††
Levetiracetam**††
Lidocaine
Lithium
Methotrexate§
N-Acetylprocainamide (NAPA)
Phenobarbital
Phenytoin
Procainamide
Theophylline
Tobramycin
Valproic Acid
Vancomycin

Thyroid
Free T4
Total T4
TSH
T Uptake

Teknik Özellikler

Weight765 lb (348 kg) Basic

783 lb (356 kg) with Heterogeneous Immunoassay (HM) Module
DimensionsWidth:  51” (129 cm)
Height:  45” (113 cm)
Depth:  31” (79 cm) 
Operating Temperature65-85°F (17-30ºC) with a maximum fluctuation of 5ºF (2.8ºC) per hour.  The system requires a maximum of 120 minutes to warm up from a cold start to the incubation temperature.
Relative Humidity20-80%
Avg Noise Output<70 dBA at 1 m while operating
Thermal Output3753 BTU/hr (1100 W)
Water UsageVery low water consumption (2 liters/hour at maximum throughput)
Power Requirements

Nominal Line
Voltage vac

115
230
 

Line Voltage
Range vac

103 to 127

207 to 253
 Nominal Line

Frequency Hz

47 to 63
47 to 63
 Maximum Continuous Current, AMPS~11
~5.5
 Power Consumption WATTS1265
1265

Share this page:

İlgili Ürünler, Servisler ve Kaynaklar

*Not available for sale in the U.S.
Alliance Application manufactured by third party, distributed by Siemens Healthcare Diagnostics.
No manual pretreatment.
§Alliance Application manufactured and distributed by Siemens Healthcare Diagnostics.
**Under development. Not available for sale.
††Manufactured by third party, distributed by Siemens Healthcare Diagnostics.

Bu web sayfasında gösterilen ürünler/özellikler her ülkede piyasada bulunmamaktadır. Mevzuata bağlı nedenlerle gelecekte bulunabileceği garanti edilemez. Lütfen daha fazla bilgi için yerel Siemens organizasyonuyla iletişime geçiniz.