ADVIA Centaur XPT Immunoassay System
An advanced automated immunoassay analyzer designed for continuous operation

ADVIA Centaur XPT Immunoassay System
 
Kontaktujte nás

The ADVIA Centaur® XPT Immunoassay System is engineered for simplified, continuous operation and timely, trusted results.

ADVIA Centaur XPT Immunoassay System

ADVIA Centaur XPT Immunoassay System

Simplify operations

Simplify operations

Simplify operations with intuitive software for comprehensive management of data and system functions, including advanced reporting capabilities.
Expand testing

Expand testing

Test from a comprehensive menu of over 70 assays
Uninterrupted Processing

Uninterrupted Processing

Enhance efficiency through uninterrupted processing when loading and unloading samples, reagents, controls and calibrators
Automation-ready

Automation-ready

Increase productivity with high throughput of up to 240 tests per hour and seamless connectivity to Siemens Healthineers automation solutions.

Features & Benefits

"The ADVIA Centaur XPT System exceeded our expectations. Furthermore, we could reduce the monthly maintenance by 12 hours per year and operator maintenance time by 60%." Dr. Roberto Rosso
ASST Ovest Milano
Laboratory Supervisor
Ospedale di Magenta

Cutting-edge AE Immunoassay Technology

  • Meet evolving clinical needs with advanced acridinium ester technology, which provides flexibility and sensitivity for new and innovative assays.
  • Manage comprehensive disease-state testing with a menu of more than 70 assays.
  • Simplify inventory management and reduce cost with the same highly stable, ready-to-use reagents used on all ADVIA Centaur analyzers.

Simplified, Continuous Operation

Learn how the ADVIA Centaur XPT System reduced analyzer maintenance by 67% at ASST Ovest Milano, Ospedale di Magenta

  • Load and unload all samples, reagents, and supplies without pausing the system.
  • Simplify operation and training with an intuitive, icon-driven user interface.
  • Reduce hands-on time with low daily maintenance and no monthly cleaning or daily startup procedures.
  • Implement new assays immediately with one easy scan of a test definition bar code.

Consistent, Predictable Turnaround Time and Accuracy

Learn how Laboratory Dr. Quade and Colleagues GmbH increased overall laboratory productivity with the ADVIA Centaur XPT Immunoassay System

  • Deliver up to 240 tests per hour for fast turnaround, even during peak workload times.
  • React fast with a STAT port that allows priority sampling at any time.
  • Improve result integrity with disposable probe tips that eliminate sample-to-sample carryover.
  • Conduct automatic repeat and confirmatory testing of reactive hepatitis B surface antigen samples using Siemens Healthineers unique SMART algorithm software. 

Seamless Connectivity

See how Labor Blackholm MVZ increased testing volume by 34% with 30% fewer analyzers

Assays

Anemia
Active B12
EPO
Ferritin
Folate
RBC Folate
Vitamin B12

 

Autoimmune
Anti-CCP

 

Bone Metabolism
Intact PTH
Vitamin D Total
 

 

Cardiac
BNP
CKMB
High-Sensitivity Troponin I (TNIH)
Myoglobin
NT-proBNP
TnI-Ultra™

 

Diabetes
C-Peptide
Insulin

 

Hepatitis
Anti-HBe
Anti-HBs 2
HAV IgM
HAV Total
HBc IgM
HBc Total
HBeAg
HBsAgII
HBsAgII Quant
HBsAg Confirmatory
HCV**
 

HIV
HIV 1/O/2 Enhanced (EHIV)§
HIV Combo§


Immunosuppressant Drugs
Cyclosporine
Everolimus*
Sirolimus*

Inflammation
IgE, Total
IL-6
LBP


Liver Fibrosis
Enhanced Liver Fibrosis (ELF™) Test
HA (ELF™ Marker)
PIIINP (ELF™ Marker)
TIMP (ELF™ Marker)


Metabolic
Cortisol
Homocysteine


 

Oncology
AFP
BR 27.29
CA 125II
CA 15-3
CA 19-9
Calcitonin
CEA
Complexed PSA
Free PSA
PSA
Serum HER-2/neu

 

Reproductive Endocrinology
AFP
Anti-Müllerian Hormone*
DHEAS
Enhanced Estradiol
Free βhCG‡‡
FSH
hCG
LH
PAPP-A‡‡
PlGF*
Progesterone
Prolactin
sFLT-1*
SHBG
Testosterone II

 

Sepsis
Procalcitonin

 

Special ID
Syphilis
EBV-EBNA IgG*
EBV-VCA IgG*
EBV-VCA IgM*
Zika IgM††

 

Therapeutic Drug Monitoring (TDM)
Carbamazepine
Digitoxin
Digoxin
Gentamicin
Phenobarbital
Phenytoin
Theophylline
Valproic Acid
Vancomycin

 

Thyroid
Anti-Tg
Anti-TPO
Free T3
Free T4
T Uptake
Total T3
Total T4
TSH3-Ultra
TSH

 

ToRCH
CMV IgG
CMV IgM*
Herpes-1 IgG
Herpes-2 IgG
Rubella IgG
Rubella IgM
Toxoplasma IgG
Toxoplasma IgM

Technical Specifications

Product Specifications 
System DescriptionRandom-access immunoassay system
Test ThroughputUp to 240 tests per hour
Time to First Result18 minutes; results every 15 seconds thereafter, assay dependent
Assays Onboard30 assays
Disease-State Assay Groups§§Allergy, Anemia/Iron Metabolism, Bone Metabolism, Cardiac, Diabetes, Hepatitis, HIV, Immunosuppressant Drugs, Liver Fibrosis, Metabolic, Oncology, Reproductive Endocrinology, Sepsis, Special ID, Therapeutic Drug Monitoring (TDM), Thyroid, ToRCH
Continuous OperationLoading/unloading of samples and consumables at any time without interrupting system operation. Includes sample racks, STATs, reagent packs, ancillary reagent packs, reaction cuvettes, sample pipette tips, calibrators, controls, wash fluids, water, and waste.
Sample Handling 
Sample Tubes3 mL, 5 mL, 7 mL, and 10 mL tubes; 1 mL and 2 mL sample cups; microcontainer tubes
Sample InputUniversal 5-position rack holds multiple tube types; 180 samples fully loaded; no-pause loading and unloading
Validated Sample TypesSerum, plasma, urine (assay-dependent)
Sample Volume per Test10–200 μL, assay-dependent
Sample Integrity ControlPressure transducer technology with clot detection, flagging, and management; short-sample detection
STAT HandlingDedicated STAT port accepts samples any time; STAT samples are processed with priority
Auto-repeatUser-definable
Sample DilutionAutomatic dilution varies by assay, up to 1:2500
Auto-reflex TestingAutomatic ability to perform additional tests based on results of first test
Sample Pipette Tips840 disposable sample tip capacity
Sample Carryover PreventionDisposable pipette tips ensure zero sample carryover
Bar Codes 
Sample Bar CodesUp to 20 digits; Interleaved 2 of 5; Code 39, Code 128, Codabar; A, B, and special characters (.-+/*$%)
Reaction Area 
Reaction CuvettesCapacity of 1000 optical-grade plastic cuvettes
Reaction BathAir bath, 37°C
Assay Result CalculationsSMART algorithm software repeats and confirms reactive testing; results available as completed
Assay TechnologyChemiluminescence using Advanced Acridinium Ester
Reagent Handling 
Reagent Tray30-position reagent tray refrigerated between 4 and 10°C (39–50°F)
Reagent Capacity Onboard30 assays
Reagent ContainersADVIA Centaur® ReadyPack® (various pack sizes available)
Reagent Integrity ControlBar-code reagent identification, automatic inventory tracking and flagging, calibration valid tracking and flagging, reagent onboard stability tracking and flagging, reagent expired/reagent low flagging
Onboard Stability28 days (average)
Reagent MixingADVIA Centaur ReadyPacks automatically rocked onboard
Ancillary Reagents25-position ancillary reagent tray cooled 4–8°C (39–46°F)
Calibration/QC 
Auto-calibration/Auto-QCAvailable automatic QC ordering by test, control, date, and time
QC DataAdvanced QC package includes Levey-Jennings plots and Westgard rules
User Interface/Data Management 
Monitor22-inch diagonal high-resolution LCD touchscreen with adjustable height
Operating SystemMicrosoft Windows 7
System DocumentationOperator manual, quickstart guide, and context-sensitive online help
Data Storage1,000,000 test/QC results; 500,000 can be historical; can archive to removable media
Onboard Maintenance LogsYes
Host InterfaceRS232C bidirectional and host query; Ethernet connection available
Host QueryYes
Remote Access & Service1000Base-T Ethernet port for remote access and modem for Siemens Remote Service
Removable Media 
Removable MediaCD, DVD, or USB
General Specifications 
Power Requirements200-240 V at 50/60 Hz; 1.2 kW maximum
Maximum Water Consumption2.5 liters (0.6 gallons) per hour
Drain RequirementsMinimum of 2.5 liters (0.6 gallons) per hour
DimensionsWith monitor: 167 (h) x 196 (w) x 104 (d) cm; 66 (h) x 77 (w) x 41 (d) in.
Without monitor: 133 (h) x 196 (w) x 104 (d) cm; 52 (h) x 77 (w) x 41 (d) in.
Weight585 kg (1289 lb)
ComplianceComplies with international environmental, health, and safety standards
Noise Emission65 dB maximum
Processing Heat Output5100 BTU/hour
Ambient Temperature18–30°C (64–86°F)
Ambient Humidity20–80% noncondensing
Floor Load-Bearing Requirement412 kg/m2 (84 lb/ft2)

 


Share this page:

Related Products, Services & Resources

* Under development. Not available for sale.
Not available for sale in the U.S.
CA 125II is a trademark of Fujirebio Diagnostics, Inc.
§ Assay developed, manufactured, and sold by Siemens Healthcare Diagnostics Inc. for Ortho Clinical Diagnostics, Inc. and Grifols Diagnostic Solutions Inc.
** For outside of the U.S. only, assay developed, manufactured, and sold by Siemens Healthcare Diagnostics Inc. for Ortho Clinical Diagnostics, Inc. and Grifols Diagnostic Solutions Inc.

†† The ADVIA Centaur Zika Test has not been FDA cleared or approved. This test has been authorized by FDA under an EUA for use by authorized laboratories. This test has been authorized only for the diagnosis for Zika virus infection and not for any other viruses or pathogens. This test is only authorized for the duration of the declaration that circumstances exist justifying the authorization of the emergency use of in vitro diagnostic tests for detection of Zika virus and/or diagnosis of Zika virus infection under section 564(b)(1) of the Act, 21 U.S.C. § 360bbb-3(b)(1), unless the authorization is terminated or revoked sooner.
‡‡ For Research Use Only in the U.S. Not for use in clinical or diagnostic procedures in the U.S.

§§ Due to local regulations, not all products are available in all countries.

The products/features (mentioned herein) are not commercially available in all countries. Due to regulatory reasons their future availability cannot be guaranteed. Please contact your local Siemens Healthineers organization for further details.

The outcomes achieved by the Siemens Healthineers customers described herein were achieved in each customer’s unique setting. Since there is no “typical” hospital and many variables exist (e.g., hospital size, case mix, level of IT adoption) there can be no guarantee that others will achieve the same results.