ADVIA 360 Hematology System
Compact footprint and remarkable accuracy in a cost-efficent system

ADVIA 360 Hematology System
 
Επικοινωνήστε Μαζί μας

As part of the Siemens Healthineers family of scalable hematology analyzers, the ADVIA® 360 Hematology System is designed to meet the specific needs of lower-volume testing environments. It efficiently generates reliable and accurate results and conserves precious benchtop space. With a compact footprint and easy-to-use interface, it offers the right fit for multiple settings—both as a primary analyzer in smaller labs and as a backup in larger labs.

ADVIA 360 Hematology System

ADVIA 360 Hematology System

Features & Benefits

The ADVIA® 360 Hematology System offers low-volume and small-scale testing environments a fast and reliable hematology solution that fits within their budget. Whether used as a stand-alone system in a satellite laboratory or a backup for a primary hematology analyzer, the easy-to-use ADVIA 360 system’s convenient features help labs optimize and manage workflow.

Fast, high-quality CBC testing in any laboratory environment

  • Runs up to 60 samples per hour
  • Processes aspiration volumes as low as 100 µL
  • Measures 22 parameters, including a 3-part white blood cell differential*
  • Allows manual sampling of both open and closed tubes
  • Conserves valuable countertop space with small footprint


Intuitive hardware features for accurate and rapid results

  • Cap-piercing function for accurate sampling and reduced biohazard risk
  • Automatic anticlogging and cleaning procedures are employed after every 15th sample
  • Easy-to-operate color touchscreen with intuitive, icon-based software
  • Choice of manual or automatic calibration
  • Handheld bar-code reader for easy entry of patient ID and control information
  • Integrated ticket printer streamlines result reporting without delaying tests in progress


Easy-to-use software features and customizable options

  • Maximum storage capacity of 10,000 results
  • Multilingual operating menu enables usability among diverse staff
  • Bidirectional LIS communication facilitates easy patient data transfer between laboratories and minimizes paper-based worklists
  • Flexible and efficient interface enables uploading of reference data via USB and QR codes
  • Customizable printing options include tabular reports
  • Built-in diagnostic flagging system automatically alerts operator to abnormal results

Assays

Technology
Volumetric impedance method

Parameters
22 parameters, including 3-part WBC differential: WBC, LYM, MID, GRA, LYM%, MID%, GRA%, RBC, MCV, HCT, HGB, MCH, MCHC, PLT, MPV, RDW-SD, RDW-CV, PCT, PDW-SD, PDW-CV, P-LCR, P-LCC

Sample Stability
Long-term sample stability studies on blood specimens drawn in K2- and K3-EDTA collection tubes at room temperature showed no significant clinical variation for all parameters between 30 minutes and 7 hours post-phlebotomy. MPV results can show instability in the first 2 hours but are stable afterwards.

Reagents
Three cyanide-free reagents (Diluent, Lyse, and Cleaner)

Technical Specifications

Performance Specifications

WBC        0.0 to 85.0 x 103/µL     
RBC0.0 to 8.0 x 106/µL
PLT0.0 to 1000 x 103/µL
HGB1.0 to 25.0 g/dL

Precision

Parameter SD%CV
WBC<0.40          <4.0            
RBC<0.15 <2.5
HGB<0.22<2.4
MCV<1.20<2.0
PLT<27<7.0

Test Selectivity/Throughput

CBCUp to 60 samples/hour  
CBC/DIFFUp to 60 samples/hour

Sample Modes/Volumes

Manual closed tube      100 µL                                                                          
Manual open tube100 µL

 

Data Management

Database            10,000-patient storage capacity
Quality control              24 QC lots, Levey-Jennings graphs, and bar-code option to load QC target values

Weight and Dimensions

Weight  

17.85 kg (39.35 lb)

Height36 cm (14.4 in.)
Width