Somatom go.Up

SOMATOM go.UpAffordable Precision

SOMATOM go.Up is a price effective modern and precise CT scanner. It offers intelligent integration of hardware and software controlled via a new intuitive user interface, letting you focus on your patient instead of operating the scanner.

  • Standardized results for precision treatment
    with quality features that provide automated patient modeling.
  • Simplified daily simulation work
    with the innovative guided simulation workflow. Simply GO with Green to the next step.
  • Affordable solution for simulation and diagnostic use
    with a modern system equipped with quality components and Radiation Therapy relevant software features, making it an ideal for everyday routine.

Features og Fordele

iMARDirectDensityMobile WorkflowOrgans RTFAST 4DShared Usage

    Klinisk brug

    Reinventing CT simulation with SOMATOM go.UP – a highly flexible, intuitive CT simulator that we designed in collaboration with over 300 RT specialists – radiation oncologists, medical physicists, dosimetrists, RTTs, and financial decision makers – to give us insights into your world. The result is a groundbreaking approach to CT simulation. It will give you everything you need to achieve the ultimate starting point for optimal RT planning, and will help you produce the most successful outcomes possible.

    Somatom go.Up - Standardized results

    New technologies and innovations are often not available for affordable CTs

    • Modern treatment techniques require precise RT planning but the latest solution might not be available for affordable CTs
    • Many patients have metal implants that can significantly impair image quality
    • Using one kV setting across the board will not deliver optimal image quality for every patient.
    • Precision for OAR contouring with AI-Rad Companion Organs RT.

    Poor image visualization effects the quality of contouring making results not suitable for precision treatment.

    • Precise target contouring with optimum kV imaging and a single calibration curve thanks to DirectDensity1
    • Confident tumor visualization thanks to automated metal artifact reduction with iMAR1
    • A straightforward 4D workflow thanks to comprehensive Respiratory Motion Management1

    Somatom go.Up

    60% of RT incidents are caused by manual operation and data exchange1

    • Successful CT simulation needs efficient and fail-safe workflows
      Different people process the data at different workstations during each stage of the process
    • Reproducible patient positioning in the treatment setup requires accurate patient marking
      Moving from station to station interrupts the simulation workflow

    The CT simulation workflow is cumbersome and error-prone.

    • Intuitive and guided CT simulation thanks to GO technologies
    • Seamless and less error-prone processes thanks to the new mobile workflow
    • A new patient-marking solution. GO with Green

    Somatom go.Up

    Latest RT functions and innovations are not always available

    • Detector and tube technology might be old
    • Modern and Intuitive workflow unavailable
    • Flexibility for shared use limited
    • Service contracts doesn’t contain hardware replacement
    • Cybersecurity update not regular

    The SOMATOM go.Up is equipped with quality technologies for Simulation and Diagnostic use.

    • Quality components
      Stellar Detector
      Chronon tube
      Tin Filter
      SAFIRE – iterative reconstruction
      2071/3071 kg RT Patient table (TG-66)
      Multi-index RTP Overlay1
    • Advance Service Plan1
      Always up-to-date (incl SW and HW)
      Flexible learning

    Tekniske specifikationer

    Bore size

    70 cm

    FOV

    sFOV 50 cm / HD FOV 70 cm

    Acquired slices/reconstruction slices

    32/64

    Rotation time

    0.81 ,1.0, 1.5 s

    Table load

    227/3071 kg (TG-66 compliant)

    System footprint

    4 m2/43 ft2 (surface area covered by gantry and moving table top)

    Min. room requirement

    12 m2 / 130 ft2

    1