SOMATOM Scope Power 32 eco
Focus on the essence

SOMATOM Scope Power 32 eco
 
Ihr Kontakt zu uns

 

How can you deliver high-quality, affordable care to as many people as possible while optimize your institution’s financial performance SOMATOM® Scope eco provides an answer – by focusing on the essence of CT. This cost-efficient scanner delivers outstanding image quality, at the right dose.
Highly reliable and easy to use, it saves you time and effort throughout your daily routine. And a flexible service model helps keep overheads under control, safeguarding your facility’s long-term competitiveness.

Eigenschaften & Vorteile


Focus on clinical excellence

Increase your clinical capabilities with a scanner that supports daily routine while striking the perfect balance between the right dose and excellent image quality for all patients1.

How can I balance CT dose and image quality?

Image quality is essential for accurate diagnosis. But minimizing radiation dose without compromising on image quality is critical for children, or patients who need multiple scans.

“We’ve been able to reduce the dosage by up to 40%2 while maintaining high levels of quality and diagnostic confidence.“
José Venâncio, MD, Head Radiologist
Portuguese Institute of Oncology Lisbon Francisco Gentil (IPOLFG), Portugal

 

How can I save time and effort in my daily CT routine?

Efficient workflows are key in today’s medical facilities. Scan preparation and image reconstruction workflows are often time-consuming, and prevent you from focusing on what matters: your patients.

"The user-friendly software has clearly enhanced clinical workflow and reduced waiting periods between scans.“
José Venâncio, MD, Head Radiologist
Portuguese Institute of Oncology Lisbon Francisco Gentil (IPOLFG), Portugal

The SOMATOM Scope eco delivers full clinical capabilities without cutting corners when it comes to performance.

  • Ultra Fast Ceramics detector (UFC) – the industry leading detector material - also used in our top-of-the-line scanners - delivers crystal clear images.
  • Combined Applications to Reduce Exposure (CARE) – enables patients to receive the right dose for their imaging requirements.
  • Adaptive Signal Boost – reduces image noise by up to 50% e.g. when imaging obese patients or patients with metal implants.
  • Fully Assisting Scanner Technologies (FAST) – optimizes your process efficiency.

Focus on cost efficiency

Improve your financial performance with innovative service benefits, a small footprint for optimum use of space, and features that help lower your TCO by up to 35%.

How can I balance patient care and budget control?

Enhancing the financial performance of your institution is key to success. You need to rely on medical technology and services that reduce baseline costs and optimize asset utilization, avoiding system and staff idle time.

 

"The SOMATOM Scope eco helped us providing high-quality care while lowering operating costs."
Prasanna Vignesh, MD, Medical Dircetor and Chief Radiologist
Aarthi Scans, India

SOMATOM Scope eco keeps your costs in check with features that help lower your total cost of ownership.

  • eCockpit – enables more cost-efficient operation with:

     eStart: extends the tube lifetime by pre-warming the tube before a scan.
     eMode: reduces wear and tear on the scanner by instantly optimizing scan parameters.
     eSleep: saves energy by stopping gantry rotation during scan breaks.

  • Small footprint – reduced space occupancy costs and low power requirements, making installation quick and easy.
  • Innovative service offerings – delivering sustainable investment protection and predictable total cost of ownership (TCO).

Klinische Anwendung


Suspected multiple metastasis in the lung

Clear visualization of detailed tumor contours. SureView reconstruction algorithm automatically selected the right pitch for the defined coverage and scan time needed for this scan.

Collimation: 16 x 0.6 mmTube settings: 130 kV, 26 mAs
Scan time: 23.8 sDLP: 110.6 mGy cm
Scan length: 342 mmCTDIvol: 3 mGy
Rotation time: 1 sEff. dose: 1.6 mSv

Scanned with eMode

(Image: Instituto Português de Oncologia de Lisboa Francisco Gentil, Portugal)


Multiple pulmonary nodules

Detailed images. Excellent spatial resolution enables perfect detection of pulmonary nodules in both lungs. syngo CT Oncology will allow their
fast evaluation, volumetric assessment, and comprehensive reporting.

Collimation: 16 x 0.6 mmTube settings: 130 kV, 42 mAs
Scan time: 19.5 sDLP: 158.2 mGy cm
Scan length: 312 mmCTDIvol: 4.81 mGy
Rotation time: 0.6 sEff. dose: 2.2 mSv

Scanned with eMode

(Image: Instituto Português de Oncologia de Lisboa Francisco Gentil, Portugal)


Obese patient with Hodgkin lymphoma

Optimized image quality in a patient with BMI 43 kg/m². Adaptive Signal Boost technology amplified low signals in image areas with high attenuation.

Collimation: 16 x 0.6 mmTube settings: 130 kV, 63 mAs
Scan time: 20.7 sDLP: 451.5 mGy cm
Scan length: 661 mmCTDIvol: 6.46 mGy
Rotation time: 0.6 sEff. dose: 6.7 mSv

Scanned with eMode
(Image: Instituto Português de Oncologia de Lisboa Francisco Gentil, Portugal)


Bladder cancer with thrombosis in the iliac veins

Excellent image quality even for large volume coverage: This patient was imaged using CARE Dose4D and IRIS, and dose was reduced to only 20% of the European Commission’s recommendations3.

Collimation: 16 x 0.6 mmTube settings: 130 kV, 63 mAs
Scan time: 20.7 sDLP: 451.5 mGy cm
Scan length: 661 mmCTDIvol: 6.46 mGy
Rotation time: 0.6 sEff. dose: 6.7 mSv

Scanned with eMode
(Image: Instituto Português de Oncologia de Lisboa Francisco Gentil, Portugal)


Cerebral ischemic stroke – Artifact-free images

The Posterior Fossa Optimization filter delivers reduced beamhardening artifacts in the base of the skull.

Collimation: 2 x 5 mmTube settings: 130 kV, 280 mAs
Scan time: 54 sDLP: 801.36 mGy cm
Scan length: 145 mmCTDIvol: 53.42 mGy
Rotation time: 2 sEff. dose: 2.5 mSv

Scanned with eMode
(Image: Aarthi Scans – Chennai, India)


Schwannoma of the left optical nerve – Detailed images

Fine collimation of up to 0.6 mm enables the clear visualization of a hyperdense tumor behind the left eyeball wrapping around the optical nerve in this pediatric patient.

Collimation: 4 x 0.6 mmTube settings: 110 kV, 188 mAs
Scan time: 29 sDLP: 188.72 mGy cm
Scan length: 49.2 mmCTDIvol: 34.75 mGy
Rotation time: 1 sEff. dose: 0.7 mSv

Scanned with eMode

(Image: Instituto Português de Oncologia de Lisboa Francisco Gentil, Portugal)


Left internal carotid artrey occlusion – Correct and speedy diagnosis

Automated Neuro Digital Subtraction technique delivers detailed CTA images free of bone for improved visualization.

Collimation: 16 x 0.6 mmTube settings: 110 kV, 96 mAs
Scan time: 18 sDLP: 2 x 564 mGy cm
Scan length: 324 mmCTDIvol: 2 x 15.22 mGy
Rotation time: 0.8 sEff. dose: 3.5 mSv

Scanned with eMode

(Image: Aarthi Scans – Chennai, India)


Cerebral aneurysm and AVM – Ready to read images.

CT angiographic images enhance diagnostic confidence of vascular malformation.

Collimation: 16 x 0.6 mmTube settings: 110 kV, 80 mAs
Scan time: 11.5 sDLP: 2 x 240.9 mGy cm
Scan length: 165 mmCTDIvol: 2 x 12.68 mGy
Rotation time: 1 sEff. dose: 0.5 mSv

Scanned with eMode

(Image: Welwitschia Hospital, Walvis Bay, Namibia)


Abdominal and pelvic CT angiography – Fine vascular details

Excellent spatial resolution enabled the sharp delineation of small vessels.

Collimation: 16 x 0.6 mmTube settings: 130 kV, 52 mAs
Scan time: 26 sDLP: 243.3 mGy cm
Scan length: 407 mmCTDIvol: 5.68 mGy
Rotation time: 0.8 sEff. dose: 3.7 mSv

Scanned with eMode

(Image: TCM hospital, Anhui, P.R. China)


Severe stenosis in the superior vena cava and the right subclavian vein – Perfectly timed angiogram

Combination of fast rotation speed and bolus tracking functionality allowed this stenosis to be clearly diagnosed.

Collimation: 16 x 0.6 mmTube settings: 130 kV, 95 mAs
Scan time: 18 sDLP: 357.3 mGy cm
Scan length: 314 mmCTDIvol: 10.74 mGy
Rotation time: 0.6 sEff. dose: 5 mSv

Scanned with eMode

(Image: Instituto Português de Oncologia de Lisboa Francisco Gentil, Portugal)


Multiple vascular stenoses and occlusion in a Runoff CTA – Detailed images

High spatial resolution enabled the sharp delineation of all structures and the visualization of multiple stenosis.
 

Collimation: 16 x 0.6 mmTube settings: 110 kV, 48 mAs
Scan time: 35 sDLP: 410 mGy cm
Scan length: 1258 mmCTDIvol: 3.14 mGy
Rotation time: 0.8 sEff. dose: 2.3 mSv

Scanned with eMode

(Image: Aarthi Scans – Chennai, India)


Bilateral iliac stenoses directly below the bifurcation – High scan speed

High pitch values enable the clear visualization of long-range vascular structures with homogenous contrast from the aorta to the foot.

Collimation: 16 x 1.2 mmTube settings: 110 kV, 60 mAs
Scan time: 32 sDLP: 470 mGy cm
Scan length: 1158 mmCTDIvol: 3.89 mGy
Rotation time: 0.8 sEff. dose: 2.6 mSv

Scanned with eMode

(Image: Aarthi Scans – Chennai, India)


Fracture of the right external femoral condyle – High-resolution bone imaging

Small focal spots, enabled by SOMATOM Scope eco tube technology, made it possible to display the smallest bone structures.

Collimation: 16 x 0.6 mmTube settings: 130 kV, 71 mAs
Scan time: 33 sDLP: 209.34 mGy cm
Scan length: 256.8 mmCTDIvol: 7.7 mGy
Rotation time: 1 sEff. dose: 0.2 mSv

Scanned with eMode

(Image: Aarthi Scans – Chennai, India)


Metal fixation of bilateral femora, left hip and knee

Minimized metal artifacts: Adaptive Signal Boost technology amplified low signals in image areas where high attenuation is present due to the metal implant.

Collimation: 16 x 0.6 mmTube settings: 130 kV, 80 mAs
Scan time: 50 sDLP: 624.5 mGy cm
Scan length: 705,2 mmCTDIvol: 8.7 mGy
Rotation time: 1 sEff. dose: 0.5 mSv

Scanned with eMode

(Image: Aarthi Scans – Chennai, India)

Technische Spezifikationen


Hardware

  • 24-row adaptive detector array
  • Max. number of slices per rotation: 16 (acquired) / 32 (reconstructed)4
  • 70 cm gantry with ±30° tilt

System software and applications

  • SureView
  • VRT
  • WorkStream4D
  • CT Angiography
  • Vessel View, with Automated Bone Removal
  • Adaptive Signal Boost
  • eCockpit: eStart, eMode and eSleep
  • iMAR (iterative Metal Artefact Reduction)4
  • Dual Spire Dual Energy4
  • IVR (Interleaved Volume Reconstruction)4

CARE applications

  • CARE Filter
  • CARE Topo
  • CARE Dose4D
  • CARE Dose Configurator
  • CARE Bolus CT
  • IRIS (Iterative Reconstruction in Image Space)
  • SAFIRE (Sinogram Affirmed Iterative Reconstruction)4

FAST applications

  • FAST Positioning
  • FAST Planning
  • FAST kV
  • FAST Wizard
  • FAST Contact
  • FAST Spine4
  • FAST 3D Align4
  • FAST IRS4

Installation requirements

  • Minimal system footprint: 8 m²
  • Power consumption ≤ 40 kVA

UFC – leading-edge detector material

Using Siemens’ proprietary Ultra Fast Ceramics (UFC), SOMATOM Scope eco provides excellent image detail even at low radiation doses. This industry-leading material5 – also used in our top-of-the-line scanners – achieves exceptional overall efficiency thanks to high X-ray absorption combined with extremely effective conversion of X-ray energy into visible light, reducing noise in the images.
SOMATOM Scope eco features the latest version of UFC, which has been continuously improved over the last years.


SureViewTM

Thanks to the SureViewTM reconstruction algorithm, SOMATOM Scope eco can produce first-rate images even at higher scan speeds. This feature provides that the scanner selects the right pitch value for the defined coverage and scan time, while retaining slice thickness and image integrity. This can be particularly valuable for performing submillimeter lung scans without reducing axial image quality.
 


Adaptive Signal Boost

Even in the most challenging cases, SOMATOM Scope eco produces excellent image quality. Adaptive Signal Boost amplifies low signals when high attenuation is present – such as when imaging obese patients or patients with metal implants. This reduces
streak artifacts, ensuring correct HU values are maintained without compromising on spatial resolution. By analyzing signal quality and integrating information from neighboring detector elements into areas with low signals, it can reduce image noise by up to 50%6.


IRIS – efficient iterative reconstruction

Iterative Reconstruction in Image Space (IRIS) delivers the same image noise reduction as raw-data-model-based iterative reconstruction, but in a fraction of the time – as the raw data is reconstructed only once. This innovative technology is ideal for cost-effective scanners: it significantly enhances spatial resolution while lowering image noise by up to 25%, enabling further dose reductions across a wide range of clinical applications. This is of particular benefit to children and patients requiring multiple scans.
 


FAST Planning

Streamlining scan preparation is a vital factor for reducing examination time. FAST Planning automatically detects anatomic regions of interest (ROI) and sets the scan parameters accordingly. This makes CT scan set-up simple and intuitive, even for less experienced technicians. In addition, FAST Planning helps increase patient safety. The automatic parameter setting enables precise organ coverage without overscanning, and limits the need for rescans due to incorrect positioning.


FAST Spine

FAST Spine4 helps streamline: the preparation of anatomically aligned spine reconstructions. The software detects and labels vertebrae within a predetermined scan area, and calculates their position for anatomically correct image reconstruction. This delivers a complete spine reconstruction in just 30 seconds6, while reducing the risk of mislabeling associated with manual preparation.


FAST 3D Align

Even in challenging situations, such as working with uncooperative patients, in pediatrics or in trauma, you need to deliver timely clear clinical findings. FAST 3D Align4 automatically corrects misalignment of anatomic structures and aligns them to fit the selected reconstruction plane – for highly automated workflows. Moreover, it allows for side-by-side comparisons and adjusts the recon field of view selection. This eliminates manual steps and repeat reconstructions, saving effort, by delivering ready-to-read data.


eCockpit

The unique eCockpit suite, standard on all SOMATOM Scope eco scanners, enables more cost-efficient operation. The entire working day of a CT system was taken into consideration, from start-up to scanning to scan breaks. The features eStart, eMode and eSleep extend the scanner’s lifespan by preventing unnecessary wear and tear, and reduce overhead costs by minimizing energy consumption. And thanks to a high degree of automation, the features can be easily integrated into everyday workflows.

Verwandte Produkte, Dienstleistungen und Ressourcen

Die auf dieser Website gezeigten Produkte/Merkmale sind nicht in allen Ländern käuflich zu erwerben. Aus medizinproduktrechtlichen Gründen kann die zukünftige Verfügbarkeit nicht zugesagt werden. Weitere Informationen erhalten Sie von der für Sie zuständigen Niederlassung von Siemens Healthineers.

1CT clinical routine for mid-sized and small healthcare facilities.

2Follow-up studies. Compared with previous 16-slice CT scanner.

3Compared with the European Commission’s recommendations (European Guidelines on Quality Criteria for Computed Tomography).

4Optional.

5Based on the number of installed systems using UFC.

6Data on file.