SOMATOM Edge Plus
in Radiation Therapy

SOMATOM Edge Plus CT scanner
SOMATOM Edge Plus
 
Contact Us

 

 

Eigenschaften & Vorteile

Changing views on patient diversity – with personalized scanning

Scan virtually all patients with diagnostic confidence – including obese persons, children, and patients unable to cooperate.  

  • How do you deal with patients with different habitus?
    Optimize image quality for every patient by combining DirectDensity® and 10kV steps in your routine.
  • How do you deal with patients with metal implants?
    Precise reduction of metal artifacts with iMAR.
  • How do you deal with motion artifacts?
    High speed scan, reconstruction and post processing combined with powerful and comprehensive motion management solutions - DirectBreathhold, FAST 4D, Mid-Ventilation approach, and 4D multimodality imaging.

 


Changing views on clinical paradigms – with advanced imaging

Improve your reputation with new level of treatment insight. Functional imaging information and tissue characterization - acquired with no dose or time penalty.

  • How can you improve treatment approach with additional information?
    Functional imaging in RT with Dual Energy CT
     
  • What if you had easy access to advanced imaging research applications?
    Get the most out of your images and revolutionize your ability to perform CT in RT research

 


Changing views on workflow solutions – with Sliding Gantry

When you need to avoid patient or applicator movement and want to benefit from excellent image quality in radiation therapy, let SOMATOM CT Sliding Gantry empower you to make treatment decisions with great confidence.

  • What if you would increase process efficiency by using Sliding Gantry CT?
    The CT gantry slides on rails over the patient, so table and accessories remain stationary.
  • What if you went beyond precise patient positioning?
    - Imaging for brachytherapy without patient and applicator motion
    - Evaluation of anatomical changes and replanning to support adaptive concepts in particle therapy
  • A successful story of strategic partnership between Siemens Healthineers and Varian: CT Sliding gantry in Varian PT room

 

Klinische Anwendung

TwinBeam Dual Energy abdomen image

TwinBeam Dual Energy - For the answers you need most

Therapy response of tumor can be evaluated faster and easier.

Courtesy of Erasmus University Medical Center, Rotterdam, The Netherlands
Head&neck and pelvis case with iMAR and without iMAR

Precise reduction of metal artifacts with iMAR1

Reliable images in challenge cases

Courtesy of University Hospital Erlangen, Erlangen, Germany
Courtesy of Luzerner Kantonsspital, Luzern, Switzerland

detection of small tumors with tin filter at the example of lung

Removal of low energy photons with Tin Filter

Very small tumors detection

Single energy – Sn100 kV
Rotation time: 0.5 s
Scan time: 5 s
Scan length: 277 mm
Slice thickness: 3 mm

Courtesy of Erasmus, Rotterdam, The Netherlands
freeze motion example of thorax

Freeze motion when your patient can’t

Image quality within seconds

Sn100 kV
Scan time: 2s
Scan length: 314 mm
CTDIvol: 0,45 mGy
DLP: 12,7 mGy cm

Courtesy of Erasmus MC, Rotterdamm, The Netherlands
kV selection example lung imaging

Use the full power of precise kV selection and high contrast for the benefit of your RT patients

10 kV Steps – Adapt your kV selection more precisely to offer excellent image quality for RT planning.

Native lung imaging – 110 kV
Scan time: 5 s
Scan length: 474 mm
CTDIvol: 9.43 mGy
DLP: 414 mGy cm

Courtesy of Erasmus MC, Rotterdam, The Netherlands
benefits of iMAR at the example of liver

You can’t choose your patients – Patient with strong metal artifact in liver

Precise reduction of metal artifacts with iMAR1

80 kV
Rotation time: 0.5 s
Scan time: 4 s
Scan lengths: 192 mm
Slice thickness: 3 mm
Contrast media: 120 ml/
320 mg Iodine/ml

Right picture: Cinematic VRT performed with syngo.via
Courtesy of Erasmus MC, Rotterdam, The Netherlands
Dual Energy Dual Spiral Acquistion different kV settings

Dual Energy allows users to display monoenergetic images for a range of 40–190 keV

By displaying multiple monoenergetic ROIs and the associated absorption curves, syngo.CT DE Monoenergetic Plus1 lets users easily compare and quantify lesions and tissues.

Courtesy of Hospital del Mar, Barcelona, Spain
Twin Beam Dual Energy example thorax CT scan

TwinBeam1 Dual Energy acquires body imaging at two different energy levels in a single scan.

Contrast enhanced acquisition with minimal contrast in a patient with impaired renal disease.

Left picture: Same window level as Dual Energy Monoenergetic Plus 45 keV image
Contrast media: 50 ml/300mg Iodine/ml
Image courtesy of National Hospital Organization Kyushu Cancer Center, Fukuoka, Japan
Twin Beam Dual Energy example brain CT scan

Dual Energy from Siemens Healthineers offers crisp image quality with no extra radiation dose

Dual Energy CT offers you clinical information beyond morphology and allows you to highlight, characterize, quantify, and differentiate the material in your scans.

2) Virtual non-contrast
Cinematic VRT is recommended for communication, education, and publication purposes and not intended for diagnostic reading; Optional
Courtesy of Erasmus, Rotterdam, The Netherlands
breath hold clinical case

Breath hold radiotherapy

DirectBreathhold1,2 facilitates Deep Inspiration Breath Hold (DIBH) acquisition at the CT scanner

Automatic triggering of the scan based on the patient‘s respiratory signal

2) Requires a gating device that can trigger the CT scanner (such as Anzai/RGSC).
Image courtesy of Maastro Clinic, Maastrich, The Netherlands

Technische Spezifikationen

Detector:StellarInfinity detector
Number of acquired slices:128
Number of reconstructed slices:384
Spatial resolution:0.30 mm
Rotation time:0.28 s
In-plane temporal resolution:142 ms
Generator power:100 kW
kV steps:70, 80, 90, 100, 110, 120, 130, 140 kV
Max. scan speed:23 cm/s
Table load:up to 307 kg / 676 lbs
Gantry opening:78 cm

 